PoE Switch Power Budget & Cat6 Cable Voltage Drop Calculator
An IEEE 802.3at (PoE+) switch delivers up to 30W at the PSE port (~25.5W usable at the device after 100m Cat5e/Cat6 resistance loss); always size total switch PoE budget with at least 20% headroom above combined device peak draw.
Interactive Parameters & Live Verdict
Rule Diagnostics & Recommendations
Engineering Formula & Verification Notes
Models IEEE 802.3 PSE-to-PD worst-case ~15% DC loop loss at 100m pure-copper Cat5e/Cat6, scaled proportionally by cable length, and checks both per-port PD ceiling and aggregate switch budget.
Worked Example: 8x Outdoor PoE Cameras + 2x Wi-Fi 7 APs
Ten devices averaging 14W each at 45m cable length consume ~150.7W at the switch PSE ports. A 180W PoE+ switch leaves ~29W (16%) margin—sufficient for simultaneous IR night activation without port brownouts.
- Avoid Copper-Clad Aluminum (CCA) Ethernet cables for PoE; higher DC resistance overheats jackets and violates UL/NEC safety.
- Use 23 AWG solid pure copper Cat6 for 60W–90W PoE++ runs.
Common PoE Deployment Mistakes
Many switches advertise "8-Port PoE" with only a 60W shared power supply.
- Ignoring total switch PoE budget when all 8 or 16 ports are populated.
- Counting camera daytime draw (4W) instead of night IR + heater peak draw (15–25W).
IEEE 802.3 PoE Standards Summary
| Standard | Max at Switch (PSE) | Guaranteed at Device (PD) |
|---|---|---|
| 802.3af (PoE) | 15.4 W | 12.95 W |
| 802.3at (PoE+) | 30.0 W | 25.50 W |
| 802.3bt Type 3 (PoE++) | 60.0 W | 51.00 W |
Frequently Asked Technical Questions
Why is guaranteed PoE wattage lower at the device than at the switch?
DC resistance over up to 100 meters of twisted-pair Ethernet cable dissipates ~15% of power as heat.
Can I use CCA (Copper-Clad Aluminum) cable for PoE?
No—CCA has ~55% higher resistance than pure copper, fails IEEE 802.3 compliance, and poses a thermal hazard under PoE+/PoE++.
What happens if a switch runs out of PoE budget?
Managed switches shut off lowest-priority ports according to port numbering or LLDP power class.