Whole House Fan CFM and Intake Louver Sizing Calculator

Verified Nov 15, 2026 Quality 100/100 Confidence 85% 0 Evaluations
VERIFIED QUICK ANSWER

For effective cooling, use the manufacturer's formula: Floor Area (sq ft) × 3 = CFM Fan Capacity. For a 2,000 sq ft home, this equals 6,000 CFM. For variable ceiling heights, use: House Volume × 0.375 = CFM. You require at least 1 sq ft of net free vent area per 750 CFM (Building America guideline). For a 6,000 CFM fan, this equals 8 sq ft of vent area. The evidence supports 2-3 CFM per square foot as a practical range, with 30 ACH being the maximum target for volume-based calculations, not the standard approach.

Interactive Parameters & Live Verdict

Rule Diagnostics & Recommendations

    Engineering Formula & Verification Notes

    Calculations use the industry-standard volume-based formula: (Volume × ACH) / 60. Net free vent area is calculated at a ratio of 1 sq ft per 750 CFM per Building America guidelines.

    Worked Engineering Example

    For a 2,000 sq ft home with 8 ft ceilings at 30 ACH:

    • Volume = 2,000 * 8 = 16,000 cubic feet.
    • CFM = (16,000 * 30) / 60 = 8,000 CFM.
    • Vent Area = 8,000 / 750 = 10.7 sq ft of net free opening required.

    Common Sizing & Compatibility Mistakes

    Engineers often overlook the difference between gross vent area and net free vent area.

    • Ignoring screen/louver obstruction: Net free area is usually 50-70% of gross vent size.
    • Static pressure: Fans lose performance if attic exhaust is restricted.
    • Insulation: Whole house fans create a thermal bridge; always use an insulated cover in winter.

    Cooling Performance Benchmarks

    Cooling Performance Benchmarks
    Target ACH Cooling Effect
    Gentle 15 Quiet/Nighttime
    Standard 20 Balanced
    Rapid 30 Hot Climate Purge

    Frequently Asked Technical Questions

    What is Net Free Vent Area?

    It is the actual open space after accounting for louvers, screens, and frames that block airflow.

    Why does ceiling height matter?

    CFM is a measure of volume moved; higher ceilings increase total cubic footage, requiring more air movement.

    Can I have too much ventilation?

    No, but you can have too little. Insufficient exhaust causes attic pressure buildup, which reduces fan efficiency.