Smart Lighting DALI Power Supply Current Draw and Maximum Loop Length Calculator

Verified Nov 22, 2026 Quality 100/100 Confidence 100% 0 Evaluations
VERIFIED QUICK ANSWER

Calculate total DALI bus current consumption by summing control gear (up to 2mA each) and bus-powered devices, ensuring total supply current does not exceed the 250mA IEC 62386 standard limit while keeping voltage drop under 2V.

Interactive Parameters & Live Verdict

Rule Diagnostics & Recommendations

    Engineering Formula & Verification Notes

    Calculations adhere to IEC 62386 standards. Total bus current consumption is determined by summing the current draw of all control gear (typically up to 2mA per control gear) plus any bus-powered control devices such as sensors and switches. The total maximum supply current from all combined power supplies on a single line must never exceed 250mA. Cable length limits are governed by a maximum allowable voltage drop of 2V across the DALI line.

    Worked Engineering Example

    Consider a standard commercial DALI line featuring 30 LED drivers (control gear) drawing 2mA each, plus 2 bus-powered occupancy sensors drawing a combined 20mA. Total device current = (30 * 2) + 20 = 80mA. If powered by a single standard 250mA DALI power supply, the system operates comfortably within limits. Using 1.5 mm² copper cable ensures the maximum loop run can reach up to 300 meters while keeping the voltage drop well under the 2V maximum threshold.

    • Control gear budget: 30 units x 2 mA = 60 mA
    • Sensor budget: 20 mA
    • Total current draw: 80 mA (well below the 250 mA cap)

    Common Sizing & Compatibility Mistakes

    The single most frequent planning error is adding a second bus power supply 'to be safe' without checking the 250mA ceiling, which forces the line outside standard compliance. Additionally, failing to account for bus-powered input devices (push-buttons, motion sensors) that draw power directly from the DALI line often leads to communication errors and erratic lighting behavior.

    • Combining multiple power supplies that push total line capacity past 250mA
    • Forgetting to include sensors and switches in the active current budget calculation
    • Ignoring voltage drop limits on longer cable runs using undersized 0.5 mm² wire

    DALI Cable Size and Distance Reference

    DALI Cable Size and Distance Reference
    Cable Cross-Section Max Recommended Run Max Voltage Drop
    0.5 mm² 100 m 2 V
    1.0 mm² 200 m 2 V
    1.5 mm² 300 m 2 V

    Frequently Asked Technical Questions

    What is the maximum allowed current on a DALI bus?

    Per the DALI-2 standard (IEC 62386), the maximum bus current from all power supplies combined cannot exceed 250 mA per line.

    How much current does a typical DALI control gear draw?

    A standard control gear (such as an LED driver or ballast) may draw up to 2 mA from the bus for communication and internal logic.

    Can I use multiple power supplies on a single DALI loop?

    Yes, multiple bus power supplies can be used, provided their combined maximum supply current does not exceed 250 mA and their total guaranteed output satisfies the device current budget.

    Did this interactive specification answer your scenario accurately?